“We looked at a cross-section of characteristics,” said DMIST principal investigator, Etta D. Pisano, M.D., Kenan professor of radiology and biomedical engineering at the University of North Carolina School of Medicine in Chapel Hill. “This paper confirms that if you are under 50, pre- or perimenopausal, and have dense breasts, you should definitely be screened with digital rather than film.”
DMIST enrolled 49,528 women at 33 centers in the U.S. and Canada. The women underwent both digital and film mammography. Breast cancer status was determined for 42,760 women.
“The original DMIST results showed that digital was statistically similar to film in the overall screening population but performed better than film in pre- and perimenopausal women under 50,” Dr. Pisano said.
For this paper, the researchers sought to retrospectively compare the accuracy of digital mammography versus film mammography in subgroups defined by combinations of age, menopausal status and breast density, using either biopsy results or follow-up information.
They compared results in 10 different subgroups of women: pre- and perimenopausal women under age 50 with fatty breasts, pre- and perimenopausal women under age 50 with dense breasts, postmenopausal women under 50 with fatty breasts, postmenopausal women under 50 with dense breasts, pre- and perimenopausal women between the ages of 50 and 64 with fatty breasts, pre- and perimenopausal women age 50 to 64 with dense breasts, postmenopausal women age 50 to 64 with fatty breasts, postmenopausal women age 50 to 64 with dense breasts, women over age 65 with fatty breasts and women over 65 with dense breasts.
The results confirmed the trial’s original findings in favor of improved diagnostic accuracy of digital mammography over film for pre- and perimenopausal women under 50 years old with dense breasts. The findings also showed a trend toward improved diagnostic accuracy of film over digital mammography for women over 65 with fatty breasts. However, this finding was not statistically significant, and further investigation is needed to determine the reason that film performed slightly better in this subgroup. For other groups evaluated, there was no significant difference.
Media Contact
More Information:
http://www.rsna.orgAll latest news from the category: Medical Engineering
The development of medical equipment, products and technical procedures is characterized by high research and development costs in a variety of fields related to the study of human medicine.
innovations-report provides informative and stimulating reports and articles on topics ranging from imaging processes, cell and tissue techniques, optical techniques, implants, orthopedic aids, clinical and medical office equipment, dialysis systems and x-ray/radiation monitoring devices to endoscopy, ultrasound, surgical techniques, and dental materials.
Newest articles
First-of-its-kind study uses remote sensing to monitor plastic debris in rivers and lakes
Remote sensing creates a cost-effective solution to monitoring plastic pollution. A first-of-its-kind study from researchers at the University of Minnesota Twin Cities shows how remote sensing can help monitor and…
Laser-based artificial neuron mimics nerve cell functions at lightning speed
With a processing speed a billion times faster than nature, chip-based laser neuron could help advance AI tasks such as pattern recognition and sequence prediction. Researchers have developed a laser-based…
Optimising the processing of plastic waste
Just one look in the yellow bin reveals a colourful jumble of different types of plastic. However, the purer and more uniform plastic waste is, the easier it is to…