A new microscope allows for high-throughput 3D adaptive optical imaging
Real-time aberration-free dynamic speckle microscopy was realized using compressed time-reversal matrix.
Microscopes are an important tool in biomedical research as it allows for detailed observation and imaging of tissues. Since biological materials are opaque by their nature, severe light scattering occurs as light travels through tissues, which induces a high level of background noise and complex optical aberration. Therefore, typical light microscopes mostly allow us to see the surface of the tissues, and details that are multiple cell layers deep are out of reach for many microscopes. This makes taking high-resolution optical images of microstructures deep inside tissues highly challenging.
About one year ago, a research group led by Prof. CHOI Wonshik from the Center for Molecular Spectroscopy and Dynamics (CMSD) within the Institute of Basic Science (IBS) showcased an imaging technique called “reflection matrix microscopy”, which combined the powers of both hardware and computational advanced adaptive optics. In contrast to conventional imaging, it measures a reflection matrix that contains all accessible information about the relationship between the input and output fields of an imaging system, including objects of interest. A clear undistorted image of the object can then be extracted from the measured matrix by post-digital image processing.
As such, the technology emerged as an appropriate candidate for label-free non-invasive high-resolution optical imaging deep inside biological tissues. The matrix imaging certainly outperforms most conventional AOs. For example, the researchers demonstrated that this technology was powerful enough to ‘see through’ an intact mouse skull and allow for accurate imaging of neurons underneath.
Despite its amazing performance, the reflection matrix microscopy was not without drawbacks. Measuring the entire reflection matrix is time-consuming and vulnerable to external perturbations because a large number of interferometric images for all accessible input illumination fields needs to be measured. While a more sparse sampling can speed up the process, insufficient sampling can lead to the limited capability to correct distortions. Therefore, this means that real-time volumetric imaging of living samples was not possible, which led to practical limitations in its application to biodynamic studies.
In the latest research published in the journal Light: Science & Applications, the same IBS group recently unveiled a new and improved version of their previous AO microscope technology. This new real-time volumetric AO imaging system enables 3D imaging over a wide depth range in highly aberrated samples while minimizing image degradation.
To speed up data acquisition, Choi’s team used a compressed sensing technique in the context of matrix imaging. They simply introduced a rotating optical diffuser in their previously deployed reflection matrix microscope to sequentially illuminate unknown speckle patterns on a sample. Then, they obtained a compressed reflection matrix by taking a much smaller number of speckle images than previously required, which reduced the matrix acquisition time by nearly 100 times.
In image post-processing, they employed a compressed “time-reversal matrix” and a unique algorithm to identify sample information and aberrations separately. The advantage of this technique is that it not only dramatically reduces matrix acquisition time but also eliminates the need for careful calibration or specific selection of illumination patterns to be used.
Compressed time-reversal matrix imaging allows for almost real-time volumetric AO imaging. The new microscope’s capabilities were demonstrated by aberration-free 3D imaging of myelin nerve fibers in a mouse brain. The data acquisition time was only 3.58 seconds for volumetric imaging of 128 × 128 × 125 μm3 tissue, with a diffraction-limited lateral resolution of 0.45 μm and an axial resolution of 2 μm.
It is expected to open a new avenue for the practical application of matrix imaging in all fields of wave engineering, including biomedical imaging. Associate Director Choi said, “Faster reflection matrix imaging technology is expected to enable real-time, nondestructive 3D optical diagnosis in the future, which will lead to faster diagnosis and advances in neuroscience research. We will further develop it to broaden the scope of its application in all wave engineering disciplines, including biomedical imaging.”
Journal: Light Science & Applications
DOI: 10.1038/s41377-021-00750-4
Method of Research: Experimental study
Subject of Research: Animals
Article Title: High-throughput volumetric adaptive optical imaging using compressed time-reversal matrix
Article Publication Date: 14-Jan-2022
Media Contact
William Suh
Institute for Basic Science
willisuh@ibs.re.kr
Office: 82-010-379-37830
All latest news from the category: Medical Engineering
The development of medical equipment, products and technical procedures is characterized by high research and development costs in a variety of fields related to the study of human medicine.
innovations-report provides informative and stimulating reports and articles on topics ranging from imaging processes, cell and tissue techniques, optical techniques, implants, orthopedic aids, clinical and medical office equipment, dialysis systems and x-ray/radiation monitoring devices to endoscopy, ultrasound, surgical techniques, and dental materials.
Newest articles
Innovative 3D printed scaffolds offer new hope for bone healing
Researchers at the Institute for Bioengineering of Catalonia have developed novel 3D printed PLA-CaP scaffolds that promote blood vessel formation, ensuring better healing and regeneration of bone tissue. Bone is…
The surprising role of gut infection in Alzheimer’s disease
ASU- and Banner Alzheimer’s Institute-led study implicates link between a common virus and the disease, which travels from the gut to the brain and may be a target for antiviral…
Molecular gardening: New enzymes discovered for protein modification pruning
How deubiquitinases USP53 and USP54 cleave long polyubiquitin chains and how the former is linked to liver disease in children. Deubiquitinases (DUBs) are enzymes used by cells to trim protein…