Implantable defibrillators save lives but may increase heart failure risk
Implantable cardioverter defibrillators (ICDs) reduce the risk of sudden cardiac death but may increase the risk of subsequent heart failure in patients who live longer, according to a study published in Circulation: Journal of the American Heart Association.
“Some patients whose lives were prolonged by ICDs were sicker and more prone to develop heart failure,” said Ilan Goldenberg, M.D., research assistant professor at the University of Rochester Medical Center and lead author of the latest report from the Multicenter Automatic Defibrillator Implantation Trial-II (MADIT-II). “The ICD kept them alive by preventing sudden cardiac death as their heart disease naturally progressed to heart failure.
“Patients who developed heart failure had almost four times the increase in risk of death during follow up. This study should direct more attention to the prevention of heart failure in patients receiving an ICD.”
The MADIT-II trial included 1,232 heart attack patients with an ejection fraction of 30 percent or less who had a heart attack at least a month before enrollment. Researchers randomly assigned patients to ICD (single or dual chamber) or best medical care.
Ejection fraction is a measure of the heart's ability to efficiently pump blood to other parts of the body. An ejection fraction of 60 percent is healthy, so the MADIT-II patients were pumping blood at about half the rate of healthy people.
Compared to patients who received only medical therapy after a heart attack, those who had ICDs implanted were 39 percent more likely to have a first hospitalization for heart failure and 58 percent more likely to be hospitalized for recurrent heart failure during an average 20-month follow up.
The overall survival benefit was 42 percent for patients who received a single chamber ICD and 51 percent for those with a dual chamber. Researchers analyzed data from 1,224 study patients, including 402 who received single-chamber devices and 313 who were implanted with dual-chamber devices.
Twenty-three percent of patients who received ICDs in the MADIT-II trial were hospitalized for HF during 20 months of follow-up versus 17 percent of patients who received only medical therapy.
Patients who received single-chamber devices did not suffer a reduced survival benefit if they developed heart failure. However, patients who were implanted with dual-chamber devices had a significant reduction in survival benefit after heart failure, Goldenberg said.
Media Contact
More Information:
http://www.heart.orgAll latest news from the category: Medical Engineering
The development of medical equipment, products and technical procedures is characterized by high research and development costs in a variety of fields related to the study of human medicine.
innovations-report provides informative and stimulating reports and articles on topics ranging from imaging processes, cell and tissue techniques, optical techniques, implants, orthopedic aids, clinical and medical office equipment, dialysis systems and x-ray/radiation monitoring devices to endoscopy, ultrasound, surgical techniques, and dental materials.
Newest articles
First-of-its-kind study uses remote sensing to monitor plastic debris in rivers and lakes
Remote sensing creates a cost-effective solution to monitoring plastic pollution. A first-of-its-kind study from researchers at the University of Minnesota Twin Cities shows how remote sensing can help monitor and…
Laser-based artificial neuron mimics nerve cell functions at lightning speed
With a processing speed a billion times faster than nature, chip-based laser neuron could help advance AI tasks such as pattern recognition and sequence prediction. Researchers have developed a laser-based…
Optimising the processing of plastic waste
Just one look in the yellow bin reveals a colourful jumble of different types of plastic. However, the purer and more uniform plastic waste is, the easier it is to…