Special probes improve ultrasound imaging in obese patients

Edited image from the publication: scan of the liver of an obese patient. The image quality of the standard ultrasound probe (left) is significantly poorer than that of the high-performance probes (centre and left).
Source: Heintz et.al. 2023, Scientific Reports

Ultrasound is used to diagnose many diseases in the abdominal cavity. A new study conducted at the University of Leipzig Medical Center and supported by the Helmholtz Institute for Metabolism, Obesity and Vascular Research (HI-MAG) shows that obesity affects the quality of ultrasound scans of the liver and kidneys. It also shows that the use of high-performance ultrasound probes can improve the anatomical depiction in these patients. The findings have been published in the journal “Scientific Reports”.

Ultrasound of the abdominal organs is a central diagnostic tool and is recommended as the first-line approach for many medical conditions. Compared with other imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI), ultrasound is readily available, avoids unnecessary radiation exposure and can be used in almost every case. However, the accuracy of this method is usually limited in obese individuals because the imaging quality of anatomical structures is impaired. To date, the degree of obesity at which ultrasound diagnostics are no longer sufficiently precise has not been sufficiently researched.

In a recent clinical study at the University of Leipzig Medical Center, researchers found that the quality of ultrasound scans of the liver and kidneys was significantly lower in obese patients. “The results showed that as the body mass index of the patients increased, the image quality of the ultrasound decreased. It also became clear that modern probes with matrix technology improve the quality of ultrasound imaging,” says Professor Thomas Karlas, head of the study and corresponding author of the current publication. The matrix probes have an improved transmitting and receiving performance and therefore achieve greater penetration depth into the tissue. This allows for better diagnostic accuracy in high-risk patients. The performance of matrix probes in obese individuals has not yet been scientifically validated.

The current data show that these relatively expensive special probes for ultrasound equipment can provide significant added value. The 40 participants in the study underwent a highly standardised ultrasound examination of the abdomen with three different probes: a standard probe and two high-performance probes. The liver and right kidney were examined in people with varying degrees of obesity, and the quality of the ultrasound imaging was scored.

“Particularly in centres that specialise in the care of obese patients, for example, in diabetology, nutritional medicine or bariatric surgery, ultrasound equipment with matrix probes should be available for abdominal examinations,” says Professor Karlas. As the senior physician and head of the Interdisciplinary Central Ultrasound Unit in the Department of Oncology, Gastroenterology, Hepatology and Pneumology at the University of Leipzig Medical Center, he also points out the following problem: “Even if matrix probes improve the quality of ultrasound imaging in obese patients, the quality is often not as good as in lean patients. Obesity therefore remains a challenge – both as a cause of secondary diseases such as metabolic liver disease – and as a limitation for widely used diagnostic methods.” A follow-up project will investigate whether specialised ultrasound applications (e.g. determination of liver fat content and liver stiffness) work better with the high-performance probes than with conventional methods.

Translation: Kerstin Gackle

Wissenschaftliche Ansprechpartner:

Professor Thomas Karlas
Head of the Interdisciplinary Central Ultrasound Unit
Department of Oncology, Gastroenterology, Hepatology and Pneumology
University of Leipzig Medical Center
Email: thomas.karlas@medizin.uni-leipzig.de

Originalpublikation:

Original publication in Scientific Reports: The application of high performance ultrasound probes increases anatomic depiction in obese patients.

Weitere Informationen:

https://doi.org/10.1038/s41598-023-43509-9

http://www.uni-leipzig.de

Media Contact

Medizinische Fakultät Anne Grimm Stabsstelle Universitätskommunikation / Medienredaktion
Universität Leipzig

All latest news from the category: Medical Engineering

The development of medical equipment, products and technical procedures is characterized by high research and development costs in a variety of fields related to the study of human medicine.

innovations-report provides informative and stimulating reports and articles on topics ranging from imaging processes, cell and tissue techniques, optical techniques, implants, orthopedic aids, clinical and medical office equipment, dialysis systems and x-ray/radiation monitoring devices to endoscopy, ultrasound, surgical techniques, and dental materials.

Back to home

Comments (0)

Write a comment

Newest articles

Innovative 3D printed scaffolds offer new hope for bone healing

Researchers at the Institute for Bioengineering of Catalonia have developed novel 3D printed PLA-CaP scaffolds that promote blood vessel formation, ensuring better healing and regeneration of bone tissue. Bone is…

The surprising role of gut infection in Alzheimer’s disease

ASU- and Banner Alzheimer’s Institute-led study implicates link between a common virus and the disease, which travels from the gut to the brain and may be a target for antiviral…

Molecular gardening: New enzymes discovered for protein modification pruning

How deubiquitinases USP53 and USP54 cleave long polyubiquitin chains and how the former is linked to liver disease in children. Deubiquitinases (DUBs) are enzymes used by cells to trim protein…