For makers of computers, disk drives and other sophisticated technologies, a guiding principle is the smoother the surfaces of chips and other components, the better these devices and the products, themselves, will function.

So, some manufacturers might be surprised to learn that a fast and increasingly popular method for measuring surface texture can yield misleading results. As reported at recent conferences and in an upcoming issue of Applied Optics,* a team of National Institute of Standards and Technology researchers has found that roughness measurements made with white light interferometric microscopes, introduced in the early 1990s, differed by as much as 80 percent from those obtained with two other surface-profiling methods.

Interferometric microscopes are used to measure surface heights, lengths and spaces by analyzing the interference patterns created by two light beams–one reflected by a reference specimen and the other by the object of interest.

To date, the team has evaluated a total of five white light instruments from three different vendors. They compared roughness measurements of gratings with both wavelike surfaces and random surfaces.

White light interferometers were compared with “phase shifting” interferometers, which use specialized single-color light sources, and with accurate, but sometimes destructive, stylus profiling instruments that trace a sharp probe over a surface. The latter two tools were in agreement across the spectrum of test samples within the expected measurement range of the phase shift interferometers. For measurements of relatively rough surfaces, white light interferometers also yielded results that corresponded closely. But for measurements of surfaces with an average roughness between 50 and 300 nanometers, results diverged significantly, peaking at about 100 nanometers.

“The discrepancy seems to be unrelated to the specific white light instrument used or to the randomness of the surface profile,” explains Ted Vorburger, head of NIST’s Surface and Microform Metrology Group.

The comparative study was carried out as part of an effort to develop international standards for three-dimensional measurements of surface texture. NIST researchers are now evaluating theoretical explanations for the observed discrepancies.

Media Contact

Mark Bello EurekAlert!

More Information:

http://www.nist.gov

All latest news from the category: Physics and Astronomy

This area deals with the fundamental laws and building blocks of nature and how they interact, the properties and the behavior of matter, and research into space and time and their structures.

innovations-report provides in-depth reports and articles on subjects such as astrophysics, laser technologies, nuclear, quantum, particle and solid-state physics, nanotechnologies, planetary research and findings (Mars, Venus) and developments related to the Hubble Telescope.

Back to home

Comments (0)

Write a comment

Newest articles

How marine worms regenerate lost body parts

The return of cells to a stem cell-like state as the key to regeneration. Many living organisms are able to regenerate damaged or lost tissue, but why some are particularly…

Nano-scale molecular detective

New on-chip device uses exotic light rays in 2D material to detect molecules. Researchers have developed a highly sensitive detector for identifying molecules via their infrared vibrational “fingerprint”. Published in Nature…

Novel CAR T-cell therapy

… demonstrates efficacy and safety in preclinical models of HER2-positive solid tumors. The p95HER2 protein is found expressed in one third of HER2+ tumors, which represent 4% of all tumors….