Stopping off-the-wall behavior in fusion reactors
Boron could help the tungsten wall inside a tokamak keep its atoms to itself.
Fusion researchers are increasingly turning to the element tungsten when looking for an ideal material for components that will directly face the plasma inside fusion reactors known as tokamaks and stellarators. But under the intense heat of fusion plasma, tungsten atoms from the wall can sputter off and enter the plasma. Too much tungsten in the plasma would substantially cool it, which would make sustaining fusion reactions very challenging. Now, researchers at the U.S. Department of Energy’s Princeton Plasma Physics Laboratory (PPPL) have experimental results suggesting that sprinkling boron powder into the tokamak could solve the problem. Boron partly shields the reactor wall from the plasma and prevents atoms from the wall from getting into the plasma. A new computer modeling framework, also led by PPPL researchers, shows the powder may only need to be sprinkled from one location. The experimental results and computer modeling framework will be presented this week at the 66th Annual Meeting of the American Physical Society Division of Plasma Physics in Atlanta.This drawing of a cross section through ITER shows the pellet injection guide tubes and a sketch of a conceptual design for a boron dropper. Credit: Oak Ridge National Laboratory / PPPL
Joseph Snipes, deputy head for Tokamak Experimental Science, is optimistic about the solid boron injection system based on experiments that demonstrated reduced tungsten sputtering after a solid boron injection. The experiments were conducted in three tungsten-walled tokamaks worldwide: one in Germany, one in China, and one in the U.S.
“The boron is sprinkled into the tokamak plasma as a powder, like from a saltshaker, which is ionized at the plasma’s edge and then deposited on the tokamak’s inner walls and the exhaust region,” he said. “Once coated with a thin layer of boron, it will stop the tungsten from getting into the plasma and radiating away the plasma energy.”
Snipes and his colleagues are working on the boron injection system with the ultimate goal of potentially using it in the ITER Organization’s reactor-scale tokamak. The injection system is well suited to the task, as it can add boron while the machine is operating. It can also precisely control and limit the amount of boron injected. The deposited boron layers retain the radioactive element tritium, which must be minimized in the ITER tokamak to comply with nuclear safety. Scientists and engineers from ITER and the Oak Ridge National Laboratory also collaborated on this project.
Florian Effenberg, a staff research physicist at PPPL, led a separate project to create a computer modeling framework for the boron injection system in the DIII-D tokamak. The framework suggests that sprinkling the boron powder from just one location may provide a sufficiently uniform distribution of boron across the reactor components considered in the simulation domain.
“We’ve developed a new way to understand how injected boron material behaves in a fusion plasma and how it interacts with the walls of fusion reactors to keep them in good condition while they are operating,” said Effenberg.
The researchers’ approach combines three different computer models to create a new framework and workflow. “One model simulates the behavior of the plasma, another shows how the boron powder particles move and evaporate in the plasma, and the third examines how the boron particles interact with the tokamak walls, including how they stick, wear away and mix with other materials,” Effenberg said.
“These insights are crucial for optimizing boron injection strategies to achieve effective and uniform wall conditioning in ITER and other fusion reactors,” Effenberg said.
While the modeling framework looked at DIII-D, a tokamak operated by General Atomics in San Diego, the next phase of this research involves scaling the modeling framework to ITER. While DIII-D’s walls are made of carbon, ITER plans to have tungsten walls, so it will be important to research any differences in how the boron protects the walls.
The following researchers also contributed to the work described by Snipes: Larry Robert Baylor, Alessandro Bortolon, Florian Effenberg, Erik Gilson, Alberto Loarte, Robert Lunsford, Rajesh Maingi, Steve Meitner, Federico Nespoli, So Maruyama, Alexander Nagy, Zhen Sun, Jeff Ulreich, Tom Wauters. Funding for this work was provided by the ITER Organization.
Klaus Schmid, Federico Nespoli and Yühe Feng worked on the modeling framework described by Effenberg in this release. Alessandro Bortolon, Jeremy Lore, Tyler Abrams, Brian Grierson, Rajesh Maingi and Dmitry Rudakov contributed to the application of that modeling framework. The work was completed with funding from DE-AC02-09CH11466, DE-FC02-04ER54698 and DE-AC05-00OR22725.
Media Contact
Rachel Kremen
DOE/Princeton Plasma Physics Laboratory
rkremen@pppl.gov
All latest news from the category: Physics and Astronomy
This area deals with the fundamental laws and building blocks of nature and how they interact, the properties and the behavior of matter, and research into space and time and their structures.
innovations-report provides in-depth reports and articles on subjects such as astrophysics, laser technologies, nuclear, quantum, particle and solid-state physics, nanotechnologies, planetary research and findings (Mars, Venus) and developments related to the Hubble Telescope.
Newest articles
Largest magnetic anisotropy of a molecule measured at BESSY II
At the Berlin synchrotron radiation source BESSY II, the largest magnetic anisotropy of a single molecule ever measured experimentally has been determined. The larger this anisotropy is, the better a…
Breaking boundaries: Researchers isolate quantum coherence in classical light systems
LSU quantum researchers uncover hidden quantum behaviors within classical light, which could make quantum technologies robust. Understanding the boundary between classical and quantum physics has long been a central question…
MRI-first strategy for prostate cancer detection proves to be safe
Active monitoring is a sufficiently safe option when prostate MRI findings are negative. There are several strategies for the early detection of prostate cancer. The first step is often a…