Laser materials processing: Tracking the contour
This enables deviations from the set contour and speed to be minimized and the energy input to be stabilized.
In recent years the use of modern solid-state lasers has brought about a distinct increase in operational speed in laser materials processing. Whether with scanners or fixed optics, high speeds – as far as possible in various axes at the same time – have almost become the norm. But although the movement of the optic is precisely calculated, the position of the processing point can deviate from the planned contour. Help is at hand, thanks to a process monitoring system which precisely tracks the relative movement of workpiece and optic. It enables acceleration-related deviations from the set contour and speed to be measured exactly and the numerical control system to be adjusted accordingly.
Research scientists at the Fraunhofer ILT in Aachen have developed a camera-based system which analyzes the movements of the workpiece through the optical axis of the laser beam before or during processing. It does not matter whether a fixed or scanner optic is used – in both cases the system measures the movement of the processing point on the workpiece and documents deviations from the set contour during machine setup or operation.
The process monitoring system uses image sequence frequencies of up to 10 kHz. In various applications, contours have been measured with a processing speed of up to 10 m/min (fixed optic) and up to 15 m/s (scanner optic). The deviation from a reference system was less than 3 cm/min. At present the measured data are evaluated separately. Whilst the same technology does permit real-time measurement (there are no technical barriers to this), the accuracy class of this has not yet been completely specified.
The special design of the system means that it can be used in a very wide range of applications, including laser cutting and welding, soldering, drilling, ablation, microjoining, SLM and hardening. The various modes of operation are interesting both for system integrators and for end users. On the one hand, the system can track the processing point during machine setup, enabling the planned contour to be adjusted.
On the other hand, the system permits process control during actual operation. This means not only can the processing contour be adjusted, the laser output can also be controlled to ensure an even energy input at different laser spot speeds. That is a critical factor in particular when processing thin materials. As a result, existing processes can be optimized and new processes are made possible.
In addition to application tests, the specialists at the Fraunhofer ILT provide full support for integration of the process monitoring system in their customers’ systems. This includes calibration of the system and adaptation to the customer’s optical equipment.
The system will be presented at LASER World of Photonics in Munich from May 23 to 26, 2011, on the joint Fraunhofer booth (Hall C2, Booth 330).
Contacts at Fraunhofer ILT
Our experts will be pleased to assist if you have any questions:
Dipl.-Ing. Christoph Franz
Sensor Technology
Phone +49 241 8906-621
christoph.franz@ilt.fraunhofer.de
Dipl.-Ing. Peter Abels
Sensor Technology
Phone +49 241 8906-428
peter.abels@ilt.fraunhofer.de
Fraunhofer Institute for Laser Technology ILT
Steinbachstrasse 15
52074 Aachen
Phone +49 241 8906-0
Fax +49 241 8906-121
Media Contact
More Information:
http://www.ilt.fraunhofer.deAll latest news from the category: Process Engineering
This special field revolves around processes for modifying material properties (milling, cooling), composition (filtration, distillation) and type (oxidation, hydration).
Valuable information is available on a broad range of technologies including material separation, laser processes, measuring techniques and robot engineering in addition to testing methods and coating and materials analysis processes.
Newest articles
Largest magnetic anisotropy of a molecule measured at BESSY II
At the Berlin synchrotron radiation source BESSY II, the largest magnetic anisotropy of a single molecule ever measured experimentally has been determined. The larger this anisotropy is, the better a…
Breaking boundaries: Researchers isolate quantum coherence in classical light systems
LSU quantum researchers uncover hidden quantum behaviors within classical light, which could make quantum technologies robust. Understanding the boundary between classical and quantum physics has long been a central question…
MRI-first strategy for prostate cancer detection proves to be safe
Active monitoring is a sufficiently safe option when prostate MRI findings are negative. There are several strategies for the early detection of prostate cancer. The first step is often a…